2W VHF/UHF Analog Portable Radios – NX-1202AV/1302AU for professional communication you can rely on.
Analog – FM
- FM Conventional Operation
- FleetSync: PTT ID, Stun/Revive,Talk back, Selcall
- MDC1200: PTT ID, Radio Inhibit/Uninhibit, Radio check, Emergency
- QT / DQT, DTMF, 2-tone
- Built-in Programmable Voice Inversion
- Scrambler (per channel)
- Built-in Compander (per channel)
Digital NXDN Mode (Optional License required)
- FDMA Very narrow 6.25 kHz & narrow 12.5 kHz bandwidths
- NXDN Conventional Operation
- Site Roaming
- Digital / Analog Mixed mode
- Group / Individual Call
- Status / Short data, Paging Call
- Remote Stun / Kill, Monitor, Check & Control
- Digital Bit Scrambler
- Late Entry
- Over-the-Air Alias (OAA)
Digital DMR Mode (Optional License required)
- TDMA 2-slot 12.5 kHz bandwidth equivalent to 6.25 kHz very narrow bandwidth
- DMR Tier II Conventional Operation
- Site Roaming
- DMR Auto Slot Select
- Dual Slot Direct Mode
- Digital / Analog Mixed mode
- Call Interruption
- Group / Individual Call
- Status / Short data, Paging Call
- Remote Stun / Kill, Monitor, Check & Control
- Enhanced Encryption (ARC4)
- Digital Bit Scrambler
- Late Entry
- Over-the-Air Alias (OAA)
Features
- RF output power 2W both on VHF/UHF
- Large 7-Color LED indicator on the top panel
- Selective Power-on LED
- Selective Call Alert LED
- Battery Level Indication
- Multi-status function indication
- Renowned KENWOOD Audio Quality: TX/RX audio profile with optimizable
- digital processor
- Audio Equalizer: Flat, High, Low
- Auto Gain Control: On, High, Low, Off
- Noise Suppressor
- Microphone type settings
- Multiple Scan Functions; Dual Priority, Single Priority, Single Zone, Multi,
- Normal Scan
- VOX & PTT triggered Semi- VOX, Voice-operated TX
- Emergency Function: Customizable Emergency Profile
- Lone Worker
- Max / Min Volume setting & Volume control
- Voice Announcement
- Remote Stun / Kill / Check
- Electronic Serial Number (ESN)
- MIL-STD-810 C/D/E/F/G
- IP54 and IP55
- Multi-protocol digital radio: Designed to operate under NXDN or DMR digital and FM
- analog protocols (Optional License required)
SPECIFICATIONS
| General |
NX-1202AV |
NX-1303AU |
| Pre-set Frequencies |
Type 1 |
136-174 MHz |
450-520 MHz |
| Max. Channels per Radio |
64 |
| Number of Zones |
4 |
| Max. Channels per Zone |
16 |
| Channel Spacing |
Analog |
30*1 / 25*1 / 15 / 12.5 kHz |
| Digital |
12.5 / 6.25 kHz |
| Power Supply |
7.5 VDC 20 % |
| Battery Life |
DMR |
Analog/NXDN |
| KNB-45L (2000mAh) |
Approx. 18 hours |
Approx. 15 hours |
| KNB-69L (2550mAh) |
Approx. 23.5 hours |
Approx. 19.5 hours |
| Operating Temperature(Radio only)*2 |
-22F to +140F (-30C to +60C) |
| Frequency Stability (-30 to +60C; +25C Ref.) |
0.5 ppm |
| Antenna Impedance |
50 |
| Dimensions |
(W x H x D) Projections Not Included |
| Radio with KNB-45L |
2.13 x 4.84 x 1.32 in (54 x 123 x 33.5 mm) |
| Radio with KNB-69L |
2.13 x 4.84 x 1.48 in (54 x 123 x 37.5 mm) |
| Weight |
(Basic model) |
(Standard keypad model) |
| Radio Only |
5.64 oz (160 g) |
| Radio with KNB-45L |
9.88 oz (280 g) |
| Radio with KNB-69L |
10.41 oz (295 g) |
| FCC ID |
Type 1 |
K44501000 |
K44501101 |
| IC Certification |
282F-501000 |
282F-501100 |
| Receiver |
NX-1202AV |
NX-1302AU |
| Sensitivity |
NXDN @ 6.25 kHz Digital (3% BER) |
0.18 V |
| NXDN @ 12.5 kHz Digital (3% BER) |
0.22 V |
| DMR @ 12.5 kHz Digital (1% BER) |
0.25 V |
| DMR @ 12.5 kHz Digital (5% BER) |
0.18 V |
| Analog @ 12.5/25 kHz (12 dB SINAD) |
0.20 V / 0.24 V |
| Selectivity |
Analog @ 12.5 / 25 kHz |
68 dB / 74 dB |
| Intermodulation Distortion |
70 dB |
| Spurious Rejection |
70 dB |
| Audio Distortion |
7% |
| Audio Output Power |
1 W / 12 (Internal Output) |
| Transmitter |
NX-1202AV |
NX-1302AU |
| RF Power Output |
(High / Low) |
2W / 1W |
| Spurious Emission |
-70 dB |
| FM Hum & Noise |
Analog @ 12.5 / 25 kHz |
40 dB / 45 dB |
| Audio Distortion |
2% |
| DMR Digital Protocol |
ETSI TS 102 361-1, -2, -3 |
| Emission Designator |
16K0F3E, 11K0F3E, 8K30F1E, 8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D, 7K60FXD, 7K60FXE |
*1 25 / 30 kHz in VHF/UHF Bands excluding T-Band are not included in the models sold in the USA or US territories.
*2 Operating temperature specification for a Li-ion battery is -10C to +60C [14F to +140F].Analog measurements made per TIA603. Specifications are measured according to applicable standards.Specifications are subject change without notice, due to advancements in technology.
FleetSync is a registered trademark of JVCKENWOOD Corporation in the United States and/or other countries.NXDN is a trademark of JVCKENWOOD Corporation and Icom Inc.NEXEDGE is a registered trademark of JVCKENWOOD Corporation.All other trademarks are the property of their respective holders.
MIL-STD & IP
| MIL Standard |
MIL 810C Methods/Procedures |
MIL 810D Methods/Procedures |
MIL 810E Methods/Procedures |
MIL 810F Methods/Procedures |
MIL 810G Methods/Procedures |
| Low Pressure |
500.1/Procedure I |
500.2/Procedure I, II |
500.3/Procedure I, II |
500.4/Procedure I, II |
500.5/Procedure I, II |
| High Temperature |
501.1/Procedure I, II |
501.2/Procedure I, II |
501.3/Procedure I, II |
501.4/Procedure I, II |
501.5/Procedure I, II |
| Low Temperature |
502.1/Procedure I |
502.2/Procedure I, II |
502.3/Procedure I, II |
502.4/Procedure I, II |
502.5/Procedure I, II |
| Temperature Shock |
503.1/Procedure I |
503.2/Procedure I |
503.3/Procedure I |
503.4/Procedure I, II |
503.5/Procedure I |
| Solar Radiation |
505.1/Procedure |
505.2/Procedure I |
505.3/Procedure I |
505.4/Procedure I |
505.5/Procedure I |
| Rain* |
506.1/Procedure I, II |
506.2/Procedure I, II |
506.3/Procedure I, II |
506.4/Procedure I, III |
506.5/Procedure I, III |
| Humidity |
507.1/Procedure I, II |
507.2/Procedure II, III |
507.3/Procedure II, III |
507.4 |
507.5/Prcedure II |
| Salt Fog |
509.1/Procedure I |
509.2/Procedure I |
509.3/Procedure I |
509.4 |
509.5 |
| Dust |
510.1/Procedure I |
510.2/Procedure I |
510.3/Procedure I |
510.4/Procedure I, III |
510.5/Procedure I |
| Vibration |
514.2/Procedure VIII, X |
514.3/Procedure I |
514.4/Procedure I |
514.5/Procedure I |
514.6/Procedure I |
| Shock |
516.2/Procedure I, II, V |
516.3/Procedure I, IV |
516.4/Procedure I, IV |
516.5/Procedure I, IV |
516.6/Procedure I, IV |
| International Protection Standard |
| Dust & Water Protection* |
IP54/55* |
To meet IP54/55, the 2-pin connector cover has to be connected on the radio or the locking bracket has to be attached to the external speaker microphone. |